4
Communication Objects
26/79 ekr CON 600 net – Process Data Exchange via Profibus
Slot Slot Name Object Function Access Description
8 ADI_Data_8_1 EkrIn_Web width
Web width measurement -
Specifying the reference
material width for the
calibration of the web
width measurement
wo
See EkrIn_Web
width, page 36.
9 ADI_Data_9_1 EkrOut_web width
Web width measurement -
Reading and validation of
the measured web width
ro
See EkrOut_Web
width, page 36.
10 ADI_Data_10_1 EkrIn_Setpoint
Writing the setpoint values
for the different guiding
modes
wo
See EkrIn_Setpoint,
page 37.
11 ADI_Data_11_1 EkrOut-Setpoint
Reading the setpoint values
for the different guiding
modes
ro
See EkrOut_Set-
point, page 38.
12 ADI_Data_12_1 EkrIn_Auto Sp Acp
Sensor positioner -
Activating the automatic
setpoint takeover
wo
See EkrIn_Auto Sp
Acp, page 39.
13 ADI_Data_13_1 EkrOut_Auto Sp Acp
Sensor positioner -
Reading the operating state
of the automatic setpoint
takeover
ro
See EkrOut_Auto Sp
Acp, page 40.
14 ADI_Data_14_1 EkrIn_POS unit
Positioning unit -
Specifying the basic settings
wo
See EkrIn_POS unit,
page 41.
15 ADI_Data_15_1 EkrOut_POS unit
Positioning unit -
Reading the positions and
positioning speeds of the
sensor slides
ro
See EkrOut_POS
unit, page 42.
16 ADI_Data_16_1 EkrIn_Direct access Reserved wo
See EkrIn_Direct
access, page 43.
17 ADI_Data_17_1 EkrOut_Direct access Reserved ro
See EkrOut_Direct
access, page 43.
18 ADI_Data_18_1 EkrIn_Machine Speed Reserved wo
See EkrIn_Machine
Speed, page 43.
19 ADI_Data_19_1 EkrOut_Machine Speed Reserved ro
See EkrOut_Ma-
chine Speed, page
43.