EasyManua.ls Logo

Buell 2006LIGHTNING MODELS - Page 590

Buell 2006LIGHTNING MODELS
638 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-34 2006 Buell Lightning: Electrical
HOME
2. Connect cables to frame and starter.
a. See Figure 7-43. First, connect positive cable to
starter using fastener with washer. Tighten fastener
to 60-85 in-lbs (7-10 Nm).
b. See Figure 7-42. Attach negative cable to frame.
Tighten to 48-72 in-lbs (5.4-8.1 Nm).
3. Apply light coat of petroleum jelly or corrosion-retardant
material to both battery terminals.
4. Connect cables to battery.
a. See Figure 7-40. Positive battery cable runs from
starter to positive battery terminal.
b. Splice 14 gauge Red/Yellow wire coming from posi-
tive battery cable into main harness bundle.
c. Connect positive cable to positive (+) battery termi-
nal using fastener.
d. Connect negative cable to negative (-) battery termi-
nal using fastener.
e. Tighten terminal fasteners to 72-96 in-lbs (8-11
Nm).
Figure 7-41. Negative Battery Cable (XB12Ss)
Figure 7-42. Negative Battery Cable
12154
8906
Figure 7-43. Positive Battery Cable
11992
1. Protective boot, positive battery cable
2. Positive battery cable
1
2

Table of Contents

Related product manuals