Appendix B Electrical Drawings Page B-1
Figure B-1: BK730-2 Tabber Base Electrical Schematic (115 VAC Line Input)
brn
red
or
yel
grn
blu
vio
grey
Shaft Encoder
"Dry Contact" control for Feeders
Speed Control Board
Upstream Remote Connector
Downstream Remote Connector
J4
(1)
(2)
(1) +12V
(2) ENC+
(3) ENC-
(4) GND
(12) GND
(11) JAM
(7) GND
(6) PHOTO
(5) +12V
(9) CYCLE
(8) +12V
(3) STOP
(1) START
(2) GND
J10
(10) GND
J10
(4) RUN MODE
CABLE #14
J8
J9
START IN (1)
GND (2)
STOP IN (3)
GND (4)
START OUT (5)
STOP OUT (7)
STOP OUT (8)
START OUT (6)
CABLE #15
RUN (9)
RUN (10)
MASTER + (11)
MASTER - (12)
ENCODER + (13)
ENCODER - (14)
8
7
10
9
12
11
14
15
19
35
36
37
34
20
JB2
J2
START IN (1)
GND (2)
STOP IN (3)
GND (4)
START OUT (5)
STOP OUT (7)
STOP OUT (8)
START OUT (6)
RUN (HEATER-) (10)
MASTER + (11)
MASTER - (12)
FOLLOW + (13)
FOLLOW - (14)
8
7
9
10
12
11
14
13
34
20
29
30
19
35
JB1
Base Control Board
RUN (HEATER+) (9)
J1
CABLE #11
CABLE #10
J6
(3) +12V
(1) GND
Jog/Run
Switch
STOP
Switch
START
Switch
On Front Panel
BLK
WH
RED
GRN
OR
BLU
WH/BLK
RED/BLK
GRN/BLK
OR/BLK
BLU/BLK
BLK/WH
RED/WH
GRN/WH
BLK
WH
RED
GRN
OR
BLU
WH/BLK
RED/BLK
GRN/BLK
OR/BLK
BLU/BLK
BLK/WH
RED/WH
GRN/WH
(5) Feed Disable
Feeder Disable
Switch
K1-1
3
5
Run
Relay
(1)
F1
5A
N’
Machine
Motor
1
(L1)
2
(L2)
M
1N
4004
blk
wh
3
(+Arm)
4
(-Arm)
Dart
Speed
Controller
Production
Pot
7
(W)
8
(Lo)
6
(Hi)
Transport Speed
Run
Relay
STACK sw (1)
STACK + (2)
RUN + (3)
RUN sw (4)
3
5
Base Motor
Control
L’
(3) +12V
(1) GND
WIPER
POTLO
POTHI
(3) MASTER +
(4) MASTER -
(1) FOLLOW +
(2) FOLLOW -
(5) ENC +
(6) ENC -
(7) PHOTO 1
(8) GND
GND (12)
PHOTO1 (10)
BASE (7)
BASE (6)
MASTER (5)
MASTER (4)
FOLLOW (3)
FOLLOW (2)
CTLOUT
CTLLO
CTLHI
JB4
red
wh
grn
blk
J5
Upper
Transport
Safety
Switch
CABLE #6
WH
BK
J4-4
J4-6
J4-5
J4-4
Product Sensor
(back)
CABLE
#4D
CABLE
#4C
BK
BK
WH
WH
J4-1
J4-3
J4-2
J4-1
Product Sensor
(front)
CABLE
#4B
CABLE
#4A
BK
BK
WH
WH
Shaft
Encoder
J3-1
J3-2
J3-3
J3-4
CABLE #15
RD RD
WH WH
WH/BN GN
BK BK
POWER
L’
N’
GND
1
32
Head
Switch
115VAC
to
Tabber
Head
J1-1
J1-2
CABLE #1
N’ L’
J1-3
N
L
1
8
4
5
2 3
7 6
MASTER - (to J1-12)
MASTER + (to J1-11)
Socket for “Master” Speed Controller
red
black
white
green
Jam Detector
CABLE #7
wh
blk
J7
CONV STOP (1)
CONV STOP (2)
J9 - Connection to
BK16XX Conveyor
J9-1 (to Conveyor Motor)
J9-2 (to Conveyor Motor)
J9-3 (Ground)
J9-7 (Stop from Conveyor)
J9-4 (Jumpered to Pin 6 in
Conveyor)
J9-5 (not connected)
J9-6 (Stop from Conveyor)
J8 - Connection
from Inkjet Base
J8-1
J8-2
J8-3
J8-4
J8-5
J8-6
J8-7
CABLE
#15
12 VDC Power Supply
NL
-+
L’N’
STOP Contacts
from Head
Buskro Ltd. BK730-2 Tabber