Remedy When E260-0Fxx (Power Supply Error in Multiple
Locations) Occurs
[Symptom]
There is the case that E260-0Fxx (the power supply error of plural points) occurs.
[Cause]
-
[Service work]
1) Check the bit display of Service Mode (Level 2) > Mode List > COPIER > Display > MISC > [PWR-GP1] to [PWR- GP16]. The
error point is the place displayed "1" in bit display.
Example) On E260-0002 (E260-0F02), the second bit from the right of [PWR-GP1] shows "1" [a].
[Reference] The following table shows that which display of [PWR- GP1] to [PWR- GP16] is compatible with which last 2 digits
of error cord.
2) If your bit display is indicated in the following corresponding table, perform a) to x) steps.
If your bit display is not indicated in the following corresponding table, take action for the error cord which is compatible with the
bit indicated in Step 1).
178