62-11785 2–14
Unit Specification Detail
Condenser Fan
Motors (Each)
Full Load Amps (FLA) 1.9 amps @ 460 VAC, 60 Hz
Horsepower 1.1 hp (820 watts) at 60 Hz
Speed 1700 rpm @ 60 Hz
Bearing lubrication Factory lubricated, additional grease not required
Rotation Clockwise when viewed from stator end
Resistance 20 to 22 ohms
Heaters
Number of heaters Heater 1: Three elements (1 assembly)
Heater 2: Four elements (1 assembly)
Resistance 97 ohms ± 10 ohms per phase
Current, Low Speed 3.5 amps nominal
Current, High Speed 4.7 amps nominal
Evaporator Fan Motor
Full Load Amps (FLA) 1.9 amps @ 460 VAC, 60 Hz
Horsepower 1.35 hp (1007 watts) @ 60 Hz
Speed 3500 rpm @ 60 Hz
Voltage and Frequency 310 to 660 VAC, 45 to 65 Hz
Bearing Lubrication Factory lubricated, additional grease not required
Rotation Clockwise when viewed from shaft end
Resistance 7 to 8 ohms
Battery Charger
Input 360 to 460 VAC, Three Phase
Output amps 40A (Maximum)
Output voltage 14.8 VDC @ 77°F (25°C)
OGF Module
Trips - On High Current 40 Amps
Trips - On Ground Fault 150mA
Battery
Voltage 12 volt nominal - Group 31, side vent
Cold cranking amps = 750 @ 0°F (-17.8°C), 454 @
-20°F or C
Power Requirements
Voltage
Current
460/3/60 with a 30A Circuit Breaker required.
(Full Load Draw = 22A, Locked Rotor Draw = 90A)
Standby Power Cable
Gauge
Length
SOOW, 600V, 90°C, 10/4 (3ph + G)
50’ minimum length, 75’ maximum length.