62-11785 2–14
Unit Specification Detail
Condenser Fan
Motors (Each)
Full Load Amps (FLA) 1.9 amps @ 460 VAC, 60 Hz
Horsepower 1.1 hp (820 watts) at 60 Hz
Speed 1700 rpm @ 60 Hz
Bearing lubrication Factory lubricated, additional grease not required
Rotation Clockwise when viewed from stator end
Resistance 20 to 22 ohms
Heaters
Number of heaters Heater 1: Three elements (1 assembly)
Heater 2: Four elements (1 assembly)
Resistance 97 ohms ± 10 ohms per phase
Current, Low Speed 3.5 amps nominal
Current, High Speed 4.7 amps nominal
Evaporator Fan Motor
Full Load Amps (FLA) 1.9 amps @ 460 VAC, 60 Hz
Horsepower 1.35 hp (1007 watts) @ 60 Hz
Speed 3500 rpm @ 60 Hz
Voltage and Frequency 310 to 660 VAC, 45 to 65 Hz
Bearing Lubrication Factory lubricated, additional grease not required
Rotation Clockwise when viewed from shaft end
Resistance 7 to 8 ohms
Battery Charger
Input 360 to 460 VAC, Three Phase
Output amps 40A (Maximum)
Output voltage 14.8 VDC @ 77°F (25°C)
OGF Module
Trips - On High Current 40 Amps
Trips - On Ground Fault 150mA
Battery
Voltage 12 volt nominal - Group 31, side vent
Cold cranking amps = 750 @ 0°F (-17.8°C), 454 @
-20°F or C
Power Requirements
Voltage
Current
460/3/60 with a 30A Circuit Breaker required.
(Full Load Draw = 22A, Locked Rotor Draw = 90A)
Standby Power Cable
Gauge
Length
SOOW, 600V, 90°C, 10/4 (3ph + G)
50’ minimum length, 75’ maximum length.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD VECTOR 8100 and is the answer not in the manual?

Carrier TRANSICOLD VECTOR 8100 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVECTOR 8100
CategoryRefrigerator
LanguageEnglish

Related product manuals