3-CONTROLSANDINSTRUMENTS
MANUALSCRCLEANINGONLYfunction
Thepurposeofthisfunctionistoavoidhightemperature
exhaustinspecicoperatingconditions:
•
Operationinsidebuilding.
•
Operationunderground.
•
Operationnearcombustiblesorexplosives.
Toenablethefunction,setMANUALSCRCLEANING
ONLYtoONintheSCRCONFIGURATIONtaboftheuser
informationmode.
SMIL14CEX4935AA11
Resumingtheoperatingmodeofthedisplay,theSCR
CLEANINGiconappearsgreenandslashed.
Afteraround35hofoperationwiththisfunctionactive,
themachinecontrolsystemwilleventuallyrequestMAN-
UALSCRCLEANING.Makesuretomovethemachine
toawellventilatedarea,andcarryouttheMANUALSCR
CLEANINGprocess.
Astheoperationinspecialconditionsisended,makesure
todisablethefunctionsettingMANUALSCRCLEANING
ONLYtoOFFintheSCRCONFIGURATIONtabofthe
userinformationmode.
SMIL14CEX2537AA12
SMIL16CEX0706AA13
3-87