8-SPECIFICATIONS
Enginecoolant
CASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANTisthereferencegenuineproductformachineservice.
NOTICE:NeveraddSupplementalCoolantAdditives(SCA)whenusingCASEAKCELAACTIFULL™OT
EXTENDEDLIFECOOLANT.
CASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANThastobeusedifrellingofthecoolingsystemis
needed.RefertothededicatedprocedureandrecommendationsdescribedinChapter6.
CASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANTmustbeusedforthereplacementofenginecoolant
accordingtothemaintenanceprogramofthemachine.Thereplacementshallalsobetackledincaseofrepairor
replacementofcomponentsofthecoolingsystem.RefertothededicatedproceduredescribedinChapter6.
Theenginecoolingsystemshouldalwaysberelledwithcoolantsolutionmadebymixtureofantifreezeanddistilled
(deionized)water.
NOTICE:Neverrellthecoolingsystemwithonlyantifreeze.Neverrellthecoolingsystemwithonlywater.
UsingCASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANT,a50/50mixtureofantifreezeanddistilled
(deionized)watergrantsproperperformanceoftheenginecoolingsystemintheabovementionedoperatingtemper-
aturerangeofthemachine.
CASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANTisavailableas:
50/50PREMIXEDcoolantsolutionreadyforusage.
CONCENTRATEantifreezetobemixed50/50withdistilled(deionized)water.
NOTICE:Ifoperatinginextremewinterclimate,acoolantsolutionmadeby60/40antifreeze/distilled(deionized)water
mixturemustbeusedinordertograntproperperformanceoftheenginecoolingsystem.
NOTICE:Neverusecoolantsolutionwithmorethan60%ofantifreeze.Thisaffectsthecoolingcapacityofthemixture.
WhenthecoolantsolutionispreparedstartingfromtheCONCENTRATEproduct,theantifreezeconcentrationinthe
mixtureofantifreezeanddistilled(deionized)watercanbedeterminedwitharefractometerdesignedtomeasure
ethyleneglycolcontent.
Ifdistilled(deionized)waterisnotavailable,usewaterfordilutionwiththefollowingproperties:
PropertyMaximumlimit
TotalSolids
340ppm
TotalHardness170ppm
Chloride(Cl)
40ppm
Sulfate(SO4)
100ppm
AciditypH5.5to9.0
NOTICE:Neverusehardwater,seawaterandsoftenedseawaterthathasbeenconditionedwithsalt.Theminerals
andsaltspresentinpotablewatercancausecorrosionanddepositsresultinginshortenedenginelife.