EasyManua.ls Logo

Case CX490D - Page 315

Case CX490D
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-ACCESSORIES
SettingrangesforSingle-actingauxiliaryhigh-owhydrauliccircuit
ThemaximumowratefortheSingle-actingauxiliaryhigh-owhydrauliccircuitcanbeselectedwithinthefollowing
range:
Level
1pumpow
1
71L/min(18.8USgpm)
2
101L/min(20.1USgpm)
3
131L/min(34.6USgpm)
4
161L/min(42.5USgpm)
5
191L/min(50.5USgpm)
6
221L/min(58.4USgpm)
7
251L/min(66.3USgpm)
8
282L/min(74.5USgpm)
9
312L/min(82.4USgpm)
10
342L/min(90.3USgpm)
ThemaximumowrateforBreaker1combinationissetfromfactory:
Single-actingcircuitBreaker1:282L/min(74.5USgpm)
ThemessageCHECKFLOWRATEappearsatthebottomofthesettingtabifavalueaboveLevel10isselected.
Ifattachmentoperationisanywaystartedwiththissetting,themessageCHECKFLOWRATEwillappearonthe
topofthedisplay,andawarningbuzzerwillsound.
Stopattachmentoperation,andmakesuretoselectavalueofmaximumowratethatdoesnotexceedLevel10.
NOTICE:theworkingpressurecanbesetfromtheinstrumentclusteronlyfortheMulti-functionauxiliaryhigh-ow
hydrauliccircuit.FortheSingle-actingcircuitandfortheDouble-actingcircuittheworkingpressureshallbesetman-
ually.
NOTICE:theworkingpressureoftheSingle-actingauxiliaryhigh-owhydrauliccircuitshallbesetmanuallybythe
reliefvalvelocatedbehindtheboomfoot.Thefactorysettingofthereliefvalvelocatedbehindtheboomfootis
17.65MPa(2560psi).Themaximumsettingofthereliefvalveis21MPa(3046psi).