© Cesab 8 – 28 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
3:546
Hardware
protection in T1
detects a short
circuit or current
through the main
contactor (Q10)
exceeds valid limit
values. Maximum
value = 2.5A,
continuous value =
1.5A
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
High power
consumption or
short circuit
1: Check for overcurrent or short
circuit:
• Check the ohms and the
amperes of the component,
compare them to the setpoint
values if they outside the
accepted range.
• Check the connections and
wiring harness for short-circuit.
• Check that the component does
not seize or is jammed.
• If points 1-3 are OK, it indicates
that the output stage is short
circuited - Replace the power-
supplying component
3:547
Hardware
protection in T1
detects a short
circuit in the output
“High Side driver”
Everything is
stopped at once,
the parking brake
is activated, and
the main
contactor opens
1: Components
are using too
much power or
wiring is short
circuited.
2: No software
compatibility
3: Short circuit in
power stage
1: Check components that are
supplied with power from the
High Side Out (Main contactor,
pump contactor (if powered
pallet truck), brake coil and
lowering valve).
• Check the ohms and the
amperes of the component,
compare them to the setpoint
values if they outside the
accepted range.
• Check the connections and
wiring harness for short-circuit.
• Check that the component does
not seize or is jammed.
• If points 1-3 are OK, it indicates
that the output stage is short
circuited - Replace the power-
supplying component
2: Update the truck software
• Update the truck software to the
latest version.
3: Replace T1
Code Description
Truck
behaviour
Error cause(s) Procedure
https://www.forkliftpdfmanuals.com/