© Cesab 5 – 44 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameter 1110 – Reset voltage for BDI
#1110 – Reset voltage for BDI
After the battery is charged to full capacity, BDI is reset to 100% provided that
battery voltage comes up to the pre-programmed reset value. If the reset
voltage value is not reached, it could be due to a voltage drop between the
battery and the logic card.
In case of reset problems:
Charge the battery to full capacity following the instructions in the
operator's manual.
Then drive the truck for at least 25 seconds before logging out.
BDI is only set to 100% if the battery has been disconnected/reconnected.
Check the voltage across the battery compared to the voltage between
wires 20 and 40 on the tiller arm logic card (A5)
A voltage drop between the battery and the logic card (A5) could be
caused by poor connectors/connections or a loose connection in the
battery connector.
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
1110 BDI 24.8 25.2 27.0 0.1 V
https://www.forkliftpdfmanuals.com/

Table of Contents

Other manuals for CESAB S210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CESAB S210 and is the answer not in the manual?

CESAB S210 Specifications

General IconGeneral
BrandCESAB
ModelS210
CategoryTrucks
LanguageEnglish

Related product manuals