© Cesab 5 – 44 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameter 1110 – Reset voltage for BDI
#1110 – Reset voltage for BDI
After the battery is charged to full capacity, BDI is reset to 100% provided that
battery voltage comes up to the pre-programmed reset value. If the reset
voltage value is not reached, it could be due to a voltage drop between the
battery and the logic card.
In case of reset problems:
• Charge the battery to full capacity following the instructions in the
operator's manual.
• Then drive the truck for at least 25 seconds before logging out.
• BDI is only set to 100% if the battery has been disconnected/reconnected.
• Check the voltage across the battery compared to the voltage between
wires 20 and 40 on the tiller arm logic card (A5)
• A voltage drop between the battery and the logic card (A5) could be
caused by poor connectors/connections or a loose connection in the
battery connector.
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
1110 BDI 24.8 25.2 27.0 0.1 V