© Cesab 8 – 48 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
8.8.3 The truck can be driven but behaves abnormally
Symptom Influencing elements Possible cause
Truck travels in wrong
direction.
Motor cable connections Incorrect U, V, W connections
Acceleration always
reduced
Operator parameter 4 Value setting low.
Reversing braking always
reduced.
Service parameter 201 Value setting low.
Neutral braking always
reduced
Operator parameter 5 Value setting low
The truck cannot be
switched off.
Parameter 102. The Red off key
on the keypad does not work.
Parameter 102 has been
incorrectly set for the log-in unit
installed in the truck.
Speed always reduced Pulse transducer [B11] Defective or disconnected pulse
transducer [B11]
Motor cable connections One of the phases U, V, W
has been disconnected
Broken wiring