© Cesab 8 – 60 T Code(s): 841, 842, 843
Repair manual: Troubleshooting Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
8.11.5 Sensilift
Move the sensilift rocker switch from the neutral position to begin the test.
The analogue value from the sensilift potentiometer is shown in mV.
8.11.6 Keypad
Press a number to start testing the keypad. “b1” up to “b11” is shown in the
display depending on which button is pressed. The numbers 0-9 are shown
as “b0” to “b9”. The red button “b10” and the green button “b11”
9: Switch off the truck by pressing the OFF button or return to the previous
menu by pressing the horn button.