EasyManua.ls Logo

CESAB S210 - Parameter 105;106 - Collision sensor sensitivity for X;Y (Optional)

CESAB S210
324 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Cesab 5 – 9 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Parameter 105/106 - Collision sensor sensitivity for X/Y (Optional)
#105 - Collision sensor X sensitivity degree
Indicates the degree of sensitivity for what should be interpreted as a frontal/
rear-end impact. 0 = Collision sensor not activated
The collision sensor can also be used in combination with DHU. In such
cases, the parameters should not be set in the truck. Collision monitoring is
instead administrated via I_Site.
This parameter must be set during truck installation.
#106 - Collision sensor Y sensitivity degree
Indicates the degree of sensitivity for what should be interpreted as a side
impact. 0 = Collision sensor not activated
The collision sensor can also be used in combination with DHU. In such
cases, the parameters should not be set in the truck. Collision monitoring is
instead administrated via I_Site.
This parameter must be set during truck installation.
Par. Description Min.
Defa
ult
Max.
Incre
ment
Unit
105
Collision sensor X-degree of
sensitivity
0 0 100 1
106
Collision sensor Y-degree of
sensitivity
0 0 100 1