© Cesab 5 – 36 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Basic option 6 - Lift height limitation by SEU input and override
Argument #1
Selection of SEU unit 1 or 2
Values Meaning
0 option is handled by SEU unit 1 (A36)
1 option is handled by SEU unit 2 (the second SEU unit)
Argument #2
Selection of SEU digital input for limitation switch
Values Meaning Pin no.
0 activates digital input 1 (1 mA) on SEU 5
1 activates digital input 2 (1 mA) on SEU 19
2 activates digital input 3 (1 mA) on SEU 33
3 activates digital input 4 (1 mA) on SEU 6
4 activates digital input 5 (7 mA) on SEU 20
5 activates digital input 6 (7 mA) on SEU 34
6 activates digital input 7 (7 mA) on SEU 7
7 activates digital input 8 (7 mA) on SEU 21
Argument #3
Selection of option switch for override function
Values Meaning
0 activated by option switch 2 or 5
1 activated by option switch 1
2 activated by option switch 2
3 activated by option switch 3
4 activated by option switch 4
5 activated by option switch 5
6 activated by option switch 6
7 activated by option switch 3 or 4
8 no override possible
Argument #4
Selection of time interval for override function
Values Meaning
0 option switch must be kept pressed for override
1-15 value corresponds to time in seconds, e.g. value 1 = 1 second