© Cesab 5 – 38 T Code(s): 841, 842, 843
Repair manual: Parameters Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040 Date: 2018-05-01 Applies from serial number: 6384351-
Argument #4
Activation/deactivation external lifting/lowering switch
Values Meaning
0 external lifting/lowering switch deactivated
1 external lifting/lowering switch activated
Basic option 13 – Activates SEU outputs at login
Argument #1
Selection of SEU unit 1 or 2
Values Meaning
0 option is handled by SEU unit 1 [A36]
1 option is handled by SEU unit 2 (the second SEU unit)
Argument #2
Selection of SEU digital output Pin no.
0 activates digital output 1 (1.6 A) on SEU 16
1 activates digital output 2 (1.6 A) on SEU 30
2 activates digital output 3 (1.6 A) on SEU 2
3 activates digital output 4 (1.6 A) on SEU 3
Argument #3
Not used
Argument #4
SEU output's connection mode
Values Meaning
0 Output continuously on
1 Output switches at 1 Hz
2 Output switches at 2 Hz
Basic option 11 - Automatic height preselector
Argument #1
Selection of SEU unit 1 or 2