EasyManua.ls Logo

Changan CS35 - Page 169

Changan CS35
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS35 2013.04
3.1.13-153 3.1.13-153Electronic Control System - ME7
2. Possible Sources
Fault
Code
Test Tactics
Setting Conditions (Control
Strategy)
Fault
P0136
The short circuit
between the post -
catalytic oxygen
sensor signal and
the heating wire
Post - catalytic oxygen sensor voltage
reaches working temperature
Oxygen sensor output voltage is
higher than 2.0 V
Sensor circuit fault
Sensor fault
ECM fault
P0137
Signal short circuit
to ground
Post - catalytic oxygen sensor output
voltage is less than 0.06 V
Post - catalytic oxygen sensor voltage
reaches working temperature
P0138
Rear oxygen volt-
age is too high
Post - catalytic oxygen sensor voltage
is higher than 1.5 V
Engine speed greater than 25 RPM
Targetvλ 1
Catalyst temperature is higher than
250
Oxygen sensor voltage reaches work-
ing temperature
Battery voltage higher than 10.68 V
P0140
Post - catalytic
oxygen sensor sig-
nal open circuit
Post - catalytic oxygen sensor voltage
reaches working temperature
Post - catalytic oxygen sensor voltage
range 0.4 ~ 0.5 V
P2270
Post - catalytic
oxygen sensor volt-
age is always low
Post - catalytic oxygen sensor voltage
is less than 0.577 V
Access to diagnosis request
P2271
Post - catalytic
oxygen sensor volt-
age is always high
Post - catalytic oxygen sensor voltage
is higher than 0.640 V
Access to diagnosis request
mashinesoft.com
09120146259

Table of Contents

Related product manuals