To validate the data, press   for 3 seconds and the   icon will disappear from the display.
Configuration values
Table 34:Configuration values: THD calculation.
THD calculation
Possible values
thd Calculation using the effective value (RMS).
THd Calculation using the fundamental value.
Press key   to access the next programming step.
 6.14.- SELECTING THE OPERATION PROFILE
The device’s operation profile is selected on this screen.
Press key   for 3 seconds to edit the value. The   icon appears at the top of the screen.
The key   jumps between the possible options.
To validate the data, press   for 3 seconds and the   icon will disappear from the display.
Configuration values
Table 35:Configuration values: Operation profile.
Operation profile
Possible values
AnALY Analyzer profile.
E3 Electrical energy efficiency profile, e
3
,
USEr User profile
Press key   to access the next programming step.
6.14.1.- SELECTING THE SCREENS THAT WILL BE DISPLAYED
Note: The following screen is displayed if you have selected the USEr profile.
This screen is used to select whether the device’s display screens are defined by the user or not.
66
CVM-C11
Instruction Manual