9. TECHNICAL FEATURES
AC Power supply 
(17)
CVM-E3-MINI-ITF - CVM-E3-MINI-MC - CVM-E3-MINI-FLEX
Rated voltage
207 ... 253 V ~  100 ... 240 V ~ ± 10%
Frequency  50 ... 60 Hz 50 ... 60 Hz
Consumption 4 VA 4.9 ... 6.1 VA
Installation category CAT III 300 V CAT III 300 V
CVM-E3-MINI-ITF-WiEth - CVM-E3-MINI-MC-WiEth - CVM-E3-MINI-FLEX-WiEth
Rated voltage
100 ... 240 V ~ ± 10%
Frequency  50 ... 60 Hz
Consumption 4 ... 5.2 VA
Installation category CAT III 300 V
DC Power supply 
(17)
CVM-E3-MINI-ITF - CVM-E3-MINI-MC - CVM-E3-MINI-FLEX
Rated voltage
100 ... 240 V    ± 10%
Consumption
3 ... 3.5 W
Installation category CAT III 300 V
CVM-E3-MINI-ITF-WiEth - CVM-E3-MINI-MC-WiEth - CVM-E3-MINI-FLEX-WiEth
Rated voltage
100 ... 240 V    ± 10%
Consumption
2.5 ... 2.8 W
Installation category CAT III 300 V
(17)
 Depending on model.
Voltage measurement circuit                                                                           
Rated voltage (Un)            300 V Ph-N,  520 V Ph-Ph
Voltage measurement margin 5 ... 120% Un
Frequency measurement margin 45 ... 65Hz
Input impedance 400 k
Min. voltage measurement (Vstart)       11 V Ph-N
Installation category CAT III 300 V
Current measurement circuit                                                                           
CVM-E3-MINI-FLEX-xxx Measure through Rogowsky sensors
Nominal current (In)
CVM-E3-MINI-ITF-xxx .../5A or .../1 A
CVM-E3-MINI-MC-xxx .../0.250 A
CVM-E3-MINI-FLEX-xxx 2000 A
Current measurement margin
CVM-E3-MINI-ITF-xxx 2 ... 120% In
CVM-E3-MINI-MC-xxx 2 ... 100% In
CVM-E3-MINI-FLEX-xxx 2 ... 120% In
Min. current measurement (Istart)
CVM-E3-MINI-ITF-xxx 0.2% In
CVM-E3-MINI-MC-xxx 0.2% In
CVM-E3-MINI-FLEX-xxx 5 A
Consumption 0.9 VA
Installation category CAT III 300 V
111
Instruction Manual
CVM-E3-MINI