5. DISPLAY
The CVM-E3-MINI has 2 operation profiles. The display screens will be opened for the corresponding 
profile:
   Analyzer profile, analyzer, 
   Electrical energy efficiency profile, e
3
,
By default, the device displays the electrical energy efficiency profile, e
3 
, press the   key to change 
from one operating profile to another.
 
 5.1.- ANALYZER PROFILE
The device displays 15 different screens for the analyzer profile (Table 18) and the voltage and 
current harmonics, up to the 31st order harmonic, for each one of the lines, L1, L2 and L3. (“5.1.4.- 
HARMONICS”).
Use keys   and   to browse the different screens.
The inst symbol on the left of the screen indicates that the values being displayed are of the 
instantaneous type. 
Table 18: Analyzer profile screens.
Screen  Parameters (units)
phase-neutral Voltage L1 (V
ph-N
) 
phase-neutral Voltage L2 (V
ph-N
) 
phase-neutral Voltage L3 (V
ph-N
) 
phase-phase Voltage L1-L2 (V
ph-ph
) 
phase-neutral Voltage L2-L3 (V
ph-ph
) 
phase-neutral Voltage L3-L1 (V
ph-ph
) 
Medium phase-neutral Voltage 
Medium phase-phase Voltage 
Frequency (Hz)