NGT—Checks and adjustments
146 NGT Transceiver System Technical Service Manual
Test equipment required
The following test equipment is required:
• a 50 MHz oscilloscope with an external trigger capability
• a 10× oscilloscope probe with an input impedance of 10 MΩ and less than 20 pF
• a 50 Ω RF dummy load and power meter rated at a minimum of 100 W RMS (rated
to 1 kW PEP (500 W CW) for high-power amplifier adjustments)
• an RF signal generator covering the range 400 kHz to 30 MHz, with a calibrated
output of –130 dBm to 0 dBm from a source impedance of 50 Ω
• a 50 MHz frequency counter with a resolution of 1 Hz
• a regulated power supply of 13.6 V ±0.2 V at 20 A peak
• two-tone audio generator operating at 700 Hz and 2300 Hz, with balance control
and adjustable output 0 to 100 mV RMS
• a digital multimeter with a 10 MΩ input impedance
• an AC voltmeter with a range of 10 mV to 10 V
• transceiver test unit to Codan drawing 04-03272 (the microphone isolating
transformer should be fitted with a µ-metal screen to prevent the 50 Hz mains from
being picked up)
• an RF spectrum analyser capable of measuring intermodulation
• NGT test handset for use with 2011 RF Units during tests that require a GPIO
connector

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan NGT 2012 RF and is the answer not in the manual?

Codan NGT 2012 RF Specifications

General IconGeneral
BrandCodan
ModelNGT 2012 RF
CategoryTransceiver
LanguageEnglish

Related product manuals