4-34 DS10 Console Reference
4.14.19 set init
The set init command sets the modem initialization string.
The initialization string is limited to 31 characters and can be modified
depending on the type of modem used.
Syntax: set init
Some typical initialization strings are:
Initialization String
Modem
at&f0e0v0x0s0=2
Motorola 3400 Lifestyle 28.8
at&f0e0v0x0s0=2
AT &T Dataport 14.4/FAX
at&fe0v0x0s0=2
Hayes Smartmodem Optima 288 V-34/V.FC + FAX
Example:
61'"WIX MRMX
-RMX7XVM RKEXJI Z\W !
61'"
Because the modem commands do not allow mixed cases, the RMC converts all
alphabetic characters entered in the init string to uppercase.
The RMC configures the modem’s flow control according to the setting of the
SRM com1_flow environment variable. The RMC also enables the modem
carrier detect feature to monitor the modem connectivity.