EasyManua.ls Logo

Comtrol DeviceMaster PRO - Managing the Devicemaster; Rebooting the Devicemaster

Comtrol DeviceMaster PRO
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DeviceMaster Installation and Configuration Guide: 2000594 Rev. F Managing the DeviceMaster - 103
Managing the DeviceMaster
This section discusses the following DeviceMaster maintenance procedures:
Rebooting the DeviceMaster
Uploading SocketServer to Multiple DeviceMasters on Page 104
Configuring Multiple DeviceMasters Network Addresses on Page 105
Note: You can configure the network addresses for multiple DeviceMasters, configure common settings for
the DeviceMasters, and save the settings to a configuration file that you can use to load settings up
to all or selected DeviceMasters.
Adding a New Device in PortVision DX on Page 105
Using the SocketServer Configuration Files on Page 107
Using Driver Configuration Files on Page 110
Changing the Bootloader Timeout on Page 114, which discusses changing the Bootloader timeout
Managing Bootloader on Page 116, which also discusses checking the Bootloader version and downloading
the latest Bootloader
Restoring Factory Defaults (Specific Models) on Page 119
Checking the NS-Link Version on Page 118
Restoring Factory Defaults (Specific Models) on Page 119
Accessing SocketServer Commands in Telnet/SSH Sessions (PortVision DX) on Page 122
Accessing RedBoot Commands in Telnet/SSH Sessions (PortVision DX) on Page 126
Note: You can optionally refer to RedBoot Procedures on Page 131 if you want to perform procedures at the
RedBoot level.
Rebooting the DeviceMaster
There are many ways to reboot the DeviceMaster.
Method Procedure
PortVision DX
Right-click the DeviceMaster or DeviceMasters in the Device List pane, click
Advanced >Reboot and then Yes.
Note: If security has been enabled in the web page, you will need to reboot the
DeviceMaster in the web page.
Web page
System | Reboot: You have 10 seconds to Cancel before the DeviceMaster
automatically reboots. Optionally, you can click Reboot Now.
Telnet Type reset.
DeviceMaster
DIN Rail Models
DeviceMaster DIN rail models have a Reset/Restore switch.
•If the Reset/Restore switch is depressed for less than 2 seconds, the
DeviceMaster reboots.
•If the Reset/Restore switch is depressed for greater than approximately 5
seconds it restores the DeviceMaster to the factory default values.

Table of Contents