Secon 5 - Engineers Program
Technical Manual
5.7.11.2 Setup Selecons - use this opon to enter the number of vends per jug.
1. Select the drink required and use the keypad to enter the number of standard cups
required for the jug.
5.7.11.3 SureVend
TM
for Jug Vend
This opon allows you to enable/disable SureVend
TM
should a glass jug be used.
5.7.12 Water Compensaon
This sub menu enables the engineer to set the Espresso water system to vend the correct
amount of water for individual site operang condions.
Important! Grinder and Auger Calibraon must be carried out before seng the Water
Compensaon
The objecve is to vend the programmed amount of water (in Selecon Timers) during a
vend. Increase or decrease the number unl the correct volume of liquid is dispensed
during a Freshbrew or Espresso vend cycle.
1. Inst Compensaon: Instant - used on LINEA machines
2. FB Compensaon: Freshbrew - low pressure drinks.
3. Esp Compensaon: Espresso - high pressure drinks .
5.7.13 Recipe Scale Factor
This menu allows the water throw to be increased or decreased globally within the machine
by up to 20%.
Note: all water related mes e.g. whipper run, post vend etc. are also changed
proporonally, the ingredient throws are NOT changed, the Water Quanty value shown in
Selecon Timers does not change.