Secon 5 - Engineer’s Program
Technical Manual
5.7.11.2 Setup Selecons - use this opon to enter the number of vends per jug.
1. Select the drink required and use the keypad to enter the number of standard cups
required for the jug.
5.7.11.3 SureVend
TM
for Jug Vend
This opon allows you to enable/disable SureVend
TM
should a glass jug be used.
5.7.12 Water Compensaon
This sub menu enables the engineer to set the Espresso water system to vend the correct
amount of water for individual site operang condions.
Important! Grinder and Auger Calibraon must be carried out before seng the Water
Compensaon
The objecve is to vend the programmed amount of water (in Selecon Timers) during a
vend. Increase or decrease the number unl the correct volume of liquid is dispensed
during a Freshbrew or Espresso vend cycle.
1. Inst Compensaon: Instant - used on LINEA machines
2. FB Compensaon: Freshbrew - low pressure drinks.
3. Esp Compensaon: Espresso - high pressure drinks .
5.7.13 Recipe Scale Factor
This menu allows the water throw to be increased or decreased globally within the machine
by up to 20%.
Note: all water related mes e.g. whipper run, post vend etc. are also changed
proporonally, the ingredient throws are NOT changed, the Water Quanty value shown in
Selecon Timers does not change.