Secon 2 - Installaon
Technical Manual
SERVICE NOTE
Baery Backup
The baery backup located on the Atlas H Board (back side of the
board) is used to maintain the date and me in case of power
interrupons or any me the main power is o.
Important: If any internal fuses become damaged or fail in any way, they must be
replaced with the correct fuse available from the manufacturer quong the
informaon wrien on the label adjacent to the relevant fuse holder.
Important: If the power cord becomes damaged in any way it must only be replaced
with one obtained from Crane Merchandising Systems.
2.4 Commissioning Procedure
A trained installaon engineer must carry out the following procedure before the machine
can be used for the rst me. Ensure that the electrical and water services to the machine
are connected correctly. Check for leaks in the water supply.
Open the front door of your machine.
Ensure that any waste buckets/trays are ed correctly. On COTI machines, clip the level
probe and overow pipes correctly onto the rim of the bucket.
Cup Turret (COTI Machines)
Note: Before lling with cups, check the scrolls on the cup drop unit are set correctly for
the size of cups used, refer to secon 2.5. Fill with the correct size cups for the cup catcher
ed to the machine. Allow the cups to drop into the tubes directly from the packaging.
DO NOT touch the cups with your hands.
Important: Do notll the tube directly above the cup dispense posion. Allow the cup
turret motor to rotate a full tube to the cup dispense posion. Rotang the cup turret by
hand will damage the mechanism.
Note: If you are using paper cups, rst inspect each sleeve for damage to the cup rims.
Damaged cups must not be used.
On powering on the machine the cup turret mechanism will index the rst stack of
available cups to the dispense posion and drop the cup stack into the cup drop
mechanism. Fill the remaining empty cup stacks with cups and replace the lid.
All Models: The water inlet valve will open and the heater tank will start to ll. As the
water heats, ensure that no water overows from the heater tank overow pipe into the
waste bucket/tray. Check the system for leaks.
All Models: As heater tanklls and heats, ensure that no water overows from overow
pipe into the waste pail / tray.
Note: The machine has a safety cut-out which will only allow the heater tank to ll for a
maximum of two minutes. If aer power-up the heater tank has not lled within this me,
the door switch should be cycled to reset the heater tank me-out.
11