C
(1) Plug
DRAINING WATER FROM
CLUTCH HOUSING(AL)
1. There is a plug under the clutch
housing.
2. Drain the water completely and
install the plug. Drain the water
into a container and dispose of it in
a proper manner for environment
protection.
T46OA42A
BLEEDING FUEL SYSTEM(AM)
Air must be removed:
1. When the fuel lter or lines are re-
moved.
2. When tank is completely empty.
3. After the tractor has not been used
for a long period of time.
Bleeding procedure is as follows:
1. Breed the system with the cock in
the fuel lter.
(1) Fuel Cock (A) Close
(B) Open (C) Air Bleeding
TE5O716A
2. Start the engine and run for about
30 seconds, and then stop the en-
gine.
3. Rotate the fuel cock to open posi-
tion.