9
TROUBLESHOOTING
9
-
5
CAUSE COUNTERMEASURES
5. Hydraulic system is
faulty
3-point hitch cannot be lifted
The transmission uid is insufcient. Add it to the specied
level.
There is air in the intake pipe. Bleed the pipe.
The oil lter is clogged. Replace it.
The hydraulic lter, valve and cylinder are malfunctioning.
Have them repaired in a workshop.
3-point hitch vibrates by itself
Set the draft control lever to the "Deep" position.
Select the highest top link hole.
6. Electric system is
faulty
Headlamps cannot be turned on or are
dim.
The fuse is blown. Check the wiring and replace the fuse.
The bulb is blown. Replace it
The ground and terminal wirings are poorly contacted. Check
and clean them.
The battery electrolyte level is low. Charge the battery.
Battery cannot be charged
Check the battery and alternator.
Horn does not sound
The horn switch is faulty. Replace or see
KIOTI
dealer.
The wiring is faulty. Replace or See
KIOTI
dealer.
The horn is damaged. Repair or replace it.
Turn signal lamps do not blink
The bulb is blown. Replace it.
The blinking device is faulty. Repair or replace it.
The ground and terminal wirings are poorly contacted. Check
and clean them.