114 • Operational Reference Linea Lite GigE Series Camera
Event Notification EventNotification Enable Events for the event type selected by the
The selected event is disabled.
On On The selected event will generate a software event.
GigEVisionEvent GigEVisionEvent
The selected event will generate a software event for SFNC
1.x compatibility.
Event Statistic Selector eventStatisticSelector Selects which Event statistic to display. Expert
DFNC
Invalid Frame Trigger InvalidFrameTrigger Counts the frame trigger occurring in an invalid Trigger
Image Lost ImageLost Image is acquired but lost before it’s been transferred.
Counts the number of individual packets that are resent.
Packet Resend Request
Dropped
PacketResendRequestDropped
Counts the number of packet resend requests dropped. The
camera queues the packet resend requests until they are
processed. There is a limit to the number of requests that
can be queued by the camera. When a new request is
received and the queue is full, the request is dropped but
this statistic is still incremented.
Ethernet Pause Frame
Received
EthernetPauseFrameReceived
Counts the number of Ethernet Pause Frame received.
Feature limited to 65536 events. See also
PAUSE Frame
Support for information on Ethernet Packet size.
Event Statistic Count eventStatisticCount Display the count of the selected Event.
Event Statistic Count
Reset
eventStatisticCountReset Reset the count of the selected Event.
DFNC
PTP Mode ptpMode Specifies the PTP (IEEE-1588: Precision Time Protocol)
operating mode as implemented by the Linea Lite.
DFNC
PTP is disabled on the device.
Automatic Automatic
PTP is enabled on the device. The camera can become a
Master or Slave device. The Master device is automatically
determined as per IEEE-1588.
Slave Slave Device will operate in PTP slave-only mode.