132 Operational Reference Linea Lite GigE Series Camera
Device Streaming Registers
Start End Command Requirements
Important: Every start command must have a corresponding end command. If not, the camera
can be in an unpredictable state. This pertains to DeviceRegistersStreamingStart,
DeviceRegistersStreamingEnd, DeviceFeaturePersistenceStart, and DeviceFeaturePersistenceEnd.
Device Registers
Streaming Start
DeviceRegistersStreamingStart
Announces the start of registers streaming without
immediate checking for consistency.
Invisible
Device Registers
Streaming End
DeviceRegistersStreamingEnd Announces end of registers streaming and performs
validation for registers consistency before activating
them.
Invisible
Device Feature
Streaming Start
DeviceFeaturePersistenceStart
Announces the start of feature streaming without
immediate checking for consistency.
Invisible
Device Feature
Streaming End
DeviceFeaturePersistenceEnd
Announces end of feature streaming and performs
validation for feature consistency before activating
them.
Invisible
Register Check DeviceRegistersCheck Performs an explicit register set validation for
consistency.
Invisible
Registers Valid DeviceRegistersValid
States if the current register set is valid and
consistent.
Invisible