84 • Operational Reference Linea Lite GigE Series Camera
Counter and Timer Control Category
The Linea Lite GigE Counter and Timer Control category groups parameters used to configure
acquisition counters, timers and signal edge detection.
Figure 69: CamExpert – Counter and Timer Control Category
Counter and Timer Control Feature Descriptions
Display Name Feature & Values Description Standard&
View
Counter Selector counterSelector Selects the counter to configure.
DFNC
Counter 1 Counter1 Select counter 1.
Counter Mode counterMode Selects the counter mode. The selected Counter is either
Active or Disabled. When Disabled, the Counter can be
DFNC
Off Off The selected Counter is Disabled.
Active Active The selected Counter is Enabled.
Counter Status counterStatus Returns the current state of the counter. (RO)
DFNC
Counter Idle CounterIdle The counter is idle.
The CounterStartSource feature is set to off.
Counter Trigger Wait CounterTriggerWait The counter is waiting for a start trigger.
Counter Active CounterActive The counter is counting for the specified duration.
Counter Completed CounterCompleted The counter reached the Counter Duration count.
The counter reached its maximum possible count.