Linea Lite GigE Series Camera Operational Reference • 93
Calibrate FPN flatfieldCalibrationFPN Performs Fixed Pattern Noise (FPN) calibration by
reducing dark pixel current to zero using a pixel
DFNC
Calibrate PRNU flatfieldCalibrationPRNU
Performs Photo Response Non-Uniformity (PRNU)
calibration to a targeted, user-defined value.
PRNU calibration eliminates the difference in
responsivity between the most and least
sensistive pixel, creating a uniform response to
DFNC
Flat Field Calibration
Width
flatfieldCalibrationROIWidth Sets the ROI Width.
Guru
DFNC
Save Calibration flatfieldCalibrationSave
Save the calibration performed by
flatfieldCalibrationFPN and flatfieldCalibrationPRNU
Expert
DFNC
Reset Coefficients flatfieldResetCoefficients Reset all FFC coefficients to pass-through. Expert
Flat Field Correction
flatfieldCorrectionColorSelector Selects the row for which to configure offset and
Beginner
DFNC
Row 1 Row1 Row 1 correction.
Row 2 Row2 Row 2 correction.
Green Green Green (row 1) correction.
Red/Blue RedBlue Red/Blue (row 2) correction.
Flat Field Correction
flatfieldCorrectionPixelXCoordinate Specifies the X coordinate of the flat field pixel
Guru
Flat Field Correction
Gain
flatfieldCorrectionGain
Sets the gain to apply to the currently selected
pixel.
Guru
DFNC
Flat Field Correction
Offset
flatfieldCorrectionOffset Sets the offset to apply to the currently selected
pixel.
Guru
DFNC