DS2400N
3
EXT TRIG A
18
19
DS2400N
EXTERNAL TRIGGER
Signal
V
Vext 30 Vdc max.
EXT TRIG B
V
CC
~
~
+
-
Figure 29 - External Trigger NPN command using external power
EXTERNAL TRIGGER
DS2400N
18
19
VS
9
25
GND
Ground
V
Signal
EXT TRIGA
EXT TRIGB
V
CC
~
~
+
-
Figure 30 - Input PNP Command Using DS2400N Power
Electrical features
: Maximum voltage: 30 Vdc
Maximum current: 12 mA
An anti-disturbance hardware filter is implemented on the External Trigger input
(< 5 milliseconds delay).
IN2 INPUT NPN Only
IN -
VS
DS2400N
INPUT
Signal
V
GND
Ground
10
25
+ 5V
Input 2 NPN command