INSTALLATION
18
SAFERY LASER SCANNER
Example of additional distance due to Ambient Interference:
From the previous example with a height of 300 mm, but in the presence of high reflec-
tive backgrounds and/or direct bright light:
Minimum safety distance
S - C
AMBIENT INTERF
= [(1600 mm/s*(0.062 s + 0.4 s)] + (1080 mm + 100 mm) = 1919.2
C
AMBIENT INTERF
(1919.2 ; detection capability = 70 mm) = 200 mm for “dust filter level” = high
(refer to "Light Interference" on page 12 and "High Reflecting Background" on page 13)
C
AMBIENT INTERF
(1919.2 ; detection capability = 70 mm) = 87 mm for “dust filter level” = low
(refer to "Light Interference" on page 12 and "High Reflecting Background" on page 13)
S = [(739.2)] + (1080 mm + 100 mm + 200 mm) = 2119.2 mm for “dust filter level” = high
S = [(739.2)] + (1080 mm + 100 mm + 87 mm) = 2006.2 mm for “dust filter level” = low