EasyManuals Logo

Datalogic Magellan 83 Product Reference Guide

Datalogic Magellan 83
558 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
5-14 Magellan
®
8300/8400
5. You have completed phase two of the increasing load test.
Blanking Test
This test ensures that the scanner/scale will indicate its weighing capability
has been exceeded if a weight greater than 0.82 over its maximum upper
weight limit is placed upon the unit.
1. Place weights that total the upper limit plus 0.82 kilograms on the
weigh platter. For example: If the upper limit is set at 15 kilograms,
place weights equaling 15.82 kilograms.
2. Verify that the display shows a dash and three hyphens ( _ - - -).
This is the overweight indication.
NOTE
The scanner/scale may blank (show an underscore and three hyphens) at any
weight greater than its upper limit, but must blank when the upper limit plus
0.82 pounds are set upon the weighing surface.

Table of Contents

Other manuals for Datalogic Magellan 83

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 83 and is the answer not in the manual?

Datalogic Magellan 83 Specifications

General IconGeneral
BrandDatalogic
ModelMagellan 83
CategoryBarcode Reader
LanguageEnglish

Related product manuals