DataBar Expanded Enable
Product Reference Guide 6-271
DataBar Expanded Length 1
Length 1 is the minimum label length if in variable length mode, or the
first fixed length if in fixed length mode (see
DataBar Expanded Length
Control). Length includes the barcode’s check and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET DataBar Expanded LENGTH 1 below.
You’ll need to cover any unused bar codes on this and the facing
page to ensure that the scanner reads only the bar code you intend
to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired label length. The selectable range for this option is
01 to 74. Pad all single and double digit numbers with leading
zeroes to yield a three-digit entry (001-074).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET DataBar Expanded LENGTH 1