RS-232 Features
Product Reference Guide 6-115
RS-232 Intercharacter Delay
Specifies delay between the end of one character and the beginning of the
next in 10-millisecond increments.
To set the RS-232 Intercharacter Delay:
1. Scan the SWITCH bar code.
2. Scan the bar code below,
SET RS-232 INTERCHARACTER
DELAY
. You’ll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired delay. The selectable range is 0-100, which is the
delay in 10-millisecond increments. Pad all single and double digit
numbers with leading zeroes to yield a three-digit entry (000-100).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
100 = 1,000ms (1 second)
4. The scanner will automatically exit Programming Mode when the
appropriate amount of digits have been scanned.
SET RS-232 INTERCHARACTER DELAY