6-284 Magellan
®
8300/8400
Code 39 Length 2
Length 2 is the maximum label length if in variable length mode, or the
second fixed length if in fixed length mode (see
Code 39 Length Control).
Length includes the barcode’s check and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET CODE 39 LENGTH 2 below. You’ll need to
cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired fixed label length. A setting of 000 will ignore this
length (only one fixed length), otherwise, the selectable range for
this option is 001 to 050. Pad all single and double digit numbers
with leading zeroes to yield a three-digit entry (001-050).
4. Complete the programming sequence by scanning the SWITCH
bar code.