Code 39
Product Reference Guide
173
Code 39 — cont.
Code 39 Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Code
39 check character. When disabled, any check character in the label is treated as a data
character
ENTER/EXIT PROGRAMMING MODE
Code 39 Check Character Calculation = Don’t Calculate
Code 39 Check Character Calculation = Calculate Std Check
Code 39 Check Character Calculation = Calculate Mod 7 Check
Code 39 Check Character Calculation = Enable Italian Post Check
Code 39 Check Character Calculation = Enable Daimler
Chrysler Check
DEFAULT

Table of Contents