EasyManuals Logo

Dell S3048-ON User Manual

Dell S3048-ON
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
* fe80::2a0:c9ff:fe00:2 fe80::3617:98ff:fe34:12 Vl 2 Up 200 200 3 O3
Dell#
Establishing BFD Sessions with OSPFv3 Neighbors for nondefault VRFs
To congure BFD in a nondefault VRF, use the following procedure:
• Enable BFD globally.
CONFIGURATION mode
bfd enable
• Establish sessions with all OSPFv3 neighbors in a specic VRF.
ROUTER-OSPFv3 mode
bfd all-neighbors
• Establish sessions with the OSPFv3 neighbors on a single interface in a specic VRF.
INTERFACE mode
ipv6 ospf bfd all-neighbors
• To disable BFD on a specic OSPFv3 enabled interface, use the ipv6 ospf bfd all-neighbors disable command. You can
also use the no bfd enable command to disable BFD on a specic interface.
NOTE: You can create upto a maximum of 200 BFD sessions (combination of OSPFv2 and OSPFv3 with a timer of 300*300*3)
for both default and nondefault VRFs.
The following example shows the conguration to establish sessions with all OSPFv3 neighbors in a specic VRF:
ipv6 router ospf 20 vrf vrf1
bfd all-neighbors
!
The following example shows the conguration to establish sessions with all OSPFv3 neighbors on a single interface in a specic VRF:
interface vlan 102
ip vrf forwarding vrf vrf1
ipv6 ospf bfd all-neighbors
The following example shows the show bfd vrf neighbors command output for nondefault VRF:
Dell#show bfd vrf vrf1 neighbors
* - Active session role
Ad Dn - Admin Down
B - BGP
C - CLI
I - ISIS
O - OSPF
O3 - OSPFv3
R - Static Route (RTM)
M - MPLS
V - VRRP
VT - Vxlan Tunnel
LocalAddr RemoteAddr Interface State Rx-int Tx-int Mult VRF
Clients
* 10.1.1.1 10.1.1.2 Vl 100 Up 150 150 3
511 O
* 11.1.1.1 11.1.1.2 Vl 101 Up 150 150 3
511 O
* 12.1.1.1 12.1.1.2 Vl 102 Up 150 150 3
511 O
152
Bidirectional Forwarding Detection (BFD)

Table of Contents

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+

Related product manuals