EasyManuals Logo

Dell S3048-ON User Manual

Dell S3048-ON
1036 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
ipv6 dhcp snooping binding mac address vlan-id vlan-id ipv6 ipv6-address interface interface-
type | interface-number lease value
Clearing the Binding Table
To clear the binding table, use the following command.
• Delete all of the entries in the binding table.
EXEC Privilege mode
clear ip dhcp snooping binding
Clearing the DHCP IPv6 Binding Table
To clear the DHCP IPv6 binding table, use the following command.
• Delete all of the entries in the binding table.
EXEC Privilege mode
clear ipv6 dhcp snooping binding
Dell# clear ipv6 dhcp snooping?
binding Clear the snooping binding database
Displaying the Contents of the Binding Table
To display the contents of the binding table, use the following command.
• Display the contents of the binding table.
EXEC Privilege mode
show ip dhcp snooping
Example of the show ip dhcp snooping Command
View the DHCP snooping statistics with the show ip dhcp snooping command.
Dell#show ip dhcp snooping
IP DHCP Snooping : Enabled.
IP DHCP Snooping Mac Verification : Disabled.
IP DHCP Relay Information-option : Disabled.
IP DHCP Relay Trust Downstream : Disabled.
Database write-delay (In minutes) : 0
DHCP packets information
Relay Information-option packets : 0
Relay Trust downstream packets : 0
Snooping packets : 0
Packets received on snooping disabled L3 Ports : 0
Snooping packets processed on L2 vlans : 142
DHCP Binding File Details
Invalid File : 0
Invalid Binding Entry : 0
Binding Entry lease expired : 0
List of Trust Ports :Gi 1/4
List of DHCP Snooping Enabled Vlans :Vl 10
List of DAI Trust ports :Gi 1/4
Dynamic Host
Conguration Protocol (DHCP) 257

Table of Contents

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+