Example of Conguring Another Monitoring Session with a Previously Used Destination Port
Dell(conf)#monitor session 300
Dell(conf-mon-sess-300)#$ destination gigabitethernet 1/4 direction tx
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP DSCP
TTL Drop Rate Gre-Protocol FcMonitor
------ ------ ----------- --- ---- --------- -------- ----
--- ---- ---- ----------- ------
0 Te 1/50 Te 1/51 rx Port N/A N/A N/A N/
A No N/A N/A yes
1 Gi 1/45 Gi 1/46 tx Port N/A N/A N/A N/
A No N/A N/A yes
2 NONE NONE N/A N/A N/A N/A N/A N/
A No N/A N/A No
300 Gi 1/17 Gi 1/4 tx Port N/A N/A N/A N/
A No N/A N/A No
Dell(conf-mon-sess-300)#
Example of Viewing a Monitoring Session
In the example below, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe has the same restriction of only four destination ports, new or
used.
Dell(conf-mon-sess-300)#do show mon session
SessID Source Destination Dir Mode Source IP Dest IP DSCP TTL Drop
Rate Gre-Protocol FcMonitor
------ ------ ----------- --- ---- --------- -------- ---- --- ----
---- ----------- ---------
0 Gi 1/13 Gi 2/1 rx interface N/A N/A 0 0 No N/
A N/A yes
10 Gi 1/14 Gi 2/2 rx interface N/A N/A 0 0 No N/
A N/A yes
20 Gi 1/15 Gi 2/3 rx interface N/A N/A 0 0 No N/
A N/A yes
30 Gi 1/16 Gi 2/4 rx interface N/A N/A 0 0 No N/
A N/A yes
100 Gi 1/25 Gi 2/5 tx interface N/A N/A 0 0 No N/
A N/A yes
110 Gi 1/26 Gi 2/5 tx interface N/A N/A 0 0 No N/
A N/A yes
300 Gi 1/17 Gi 2/5 tx interface N/A N/A 0 0 No N/
A N/A yes
Dell(conf-mon-sess-5)#
Given these parameters, the following illustration shows the possible port monitoring congurations.
Figure 90. Port Monitoring Congurations
Dell Networking OS Behavior: All monitored frames are tagged if the congured monitoring direction is egress (TX), regardless of whether
the monitored port (MD) is a Layer 2 or Layer 3 port. If the MD port is a Layer 2 port, the frames are tagged with the VLAN ID of the
VLAN to which the MD belongs. If the MD port is a Layer 3 port, the frames are tagged with VLAN ID 4095. If the MD port is in a Layer 3
VLAN, the frames are tagged with the respective Layer 3 VLAN ID. For example, in the conguration source Gig 6/1 destination Gig 6/2