VLT DOMAIN CONFIGURATION mode
primary-priority value
The priority values are from 1 to 65535. The default is 32768.
If the primary peer fails, the secondary peer (with the higher priority) takes the primary role. If the primary peer (with the lower
priority) later comes back online, it is assigned the secondary role (there is no preemption).
6 (Optional) Prevent a possible loop during the bootup of a VLT peer switch or a device that accesses the VLT domain.
CONFIGURATION mode
lacp ungroup member-independent {vlt | port-channel port-channel-id}
LACP on VLT ports (on a VLT switch or access device), which are members of the virtual link trunk, is not brought up until the VLT
domain is recognized on the access device.
7 Repeat Steps 1 to 5 on the VLT peer switch to congure the IP address of this switch as the endpoint of the VLT backup link and to
congure the same port channel for the VLT interconnect.
Conguring a VLT Backup Link
To congure a VLT backup link, use the following command.
1 Specify the management interface to be used for the backup link through an out-of-band management network.
CONFIGURATION mode
interface managementethernet slot/port
Enter the slot (0-1) and the port (0).
2 Congure an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) and mask (/x) on the interface.
MANAGEMENT INTERFACE mode
{ip address ipv4-address/ mask | ipv6 address ipv6-address/ mask}
This is the IP address to be congured on the VLT peer with the back-up destination command.
3 Ensure that the interface is active.
MANAGEMENT INTERFACE mode
no shutdown
4 Congure a VLT backup link using the IPv4 or IPv6 address of the VLT peer’s management interface.
MANAGEMENT INTERFACE mode
back-up destination {ip address ipv4-address/ mask | ipv6 address ipv6-address/ mask}
5 Repeat Steps 1 to 4 on the VLT peer switch.
To set an amount of time, in seconds, to delay the system from restoring the VLT port, use the delay-restore command at any time.
For more information, refer to
VLT Port Delayed Restoration.
Conguring a VLT Port Delay Period
To congure a VLT port delay period, use the following commands.
1 Enter VLT-domain conguration mode for a specied VLT domain.
900
Virtual Link Trunking (VLT)

Table of Contents

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+