Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-83
Settings 0 to 19
Settings Functions Descriptions
0 Output frequency (Hz) Max. frequency Pr.01-00 is regarded as 100%.
1
Frequency command
(Hz)
Max. frequency Pr.01-00 is regarded as 100%.
2 Motor speed (Hz) 600Hz is regarded as 100%
3 Output current (rms) 2.5 X rated current is regarded as 100%
4 Output voltage 2 X rated voltage is regarded as 100%
5 DC Bus Voltage 450V (900V)=100%
6 Power factor -1.000~1.000=100%
7 Power Rated power is regarded as 100%
8 Output torque Full-load torque is regarded as 100%
9 AVI 0~10V=0~100%
10 ACI 0~20mA=0~100%
11 AUI -10~10V=0~100%
12 q-axis current (2.5 X rated current) is regarded as 100%
13 q-axis feedback value (2.5 X rated current) is regarded as 100%
14 d-axis current
(2.5 X rated current) is regarded as 100%
15 d-axis feedback value
(2.5 X rated current) is regarded as 100%
16 q-axis voltage 250V (500V) =100%
17 d-axis voltage 250V (500V) =100%
18 Torque command Rated torque is regarded as 100%