Chapter 4 Parameters|
4-30 Revision August 2008, 03VE, SW V2.04
New settings 44~50 for Pr.02-00~Pr.02-06 and new parameter 02-43.
Pr. Explanation Settings
Factory
Setting
VF
VFPG
SVC
FOCPG
TQRPG
02-00 2-wire/3-wire Operation
Control
0: FWD/STOP, REV/STOP
1: FWD/STOP, REV/STOP (Line Start Lockout)
2: RUN/STOP, REV/FWD
3: RUN/STOP, REV/FWD (Line Start Lockout)
4: 3-wire (momentary push button)
5: 3-wire (momentary push button and Line Start
Lockout)
0
0: no function
1: multi-step speed command 1/multi-step position
command 1
02-01 Multi-Function Input
Command 1 (MI1)
(it is Stop terminal for 3-
wire operation)
2: multi-step speed command 2/ multi-step position
command 2
1
3: multi-step speed command 3/ multi-step position
command 3
02-02
Multi-Function Input
Command 2 (MI2)
4: multi-step speed command 4/ multi-step position
command 4
2
5: Reset
02-03
Multi-Function Input
Command 3 (MI3)
6: JOG command
3
7: acceleration/deceleration speed inhibit
4
02-04
Multi-Function Input
Command 4 (MI4)
8: the 1st, 2nd
acceleration/deceleration time selection
9: the 3rd, 4th
acceleration/deceleration time selection
0
02-05
Multi-Function Input
Command 5 (MI5)
10: EF input (07-36)
11: B.B. input
0
02-06 Multi-Function Input
Command 6 (MI6)
(specific terminal for
TRG)
12: Output stop
02-23 Multi-Function Input
Command 7
13: cancel the setting of the optimal
acceleration/deceleration time
0
02-24 Multi-Function Input
Command 8
14: switch between drive settings 1 and 2
0
02-25 Multi-Function Input
Command 9
15: operation speed command form AVI
0
02-26 Multi-Function Input
Command 10
16: operation speed command form ACI
0
02-27 Multi-Function Input
Command 11
17: operation speed command form AUI
0
02-28 Multi-Function Input
Command 12
18: Emergency Stop (07-36)
0
02-29 Multi-Function Input
Command 13
19: Digital Up command
0
02-30 Multi-Function Input
Command 14
20: Digital Down command
0
21: PID function disabled
22: clear counter
23: input the counter value (multi-function input
command 6)
24: FWD JOG command
25: REV JOG command
26: TQC+PG/FOC+PG model selection
27: ASR1/ASR2 selection
28: Emergency stop (EF1)
29: Signal confirmation for Y-connection
30: Signal confirmation for Δ−connection
31: High torque bias (by Pr.07-29)
32: Middle torque bias (by Pr.07-30)
33: Low torque bias (by Pr.07-31)
34: Enable multi-step position control
35: Enable position control
36: Enable position learning function (valid at stop)
37: Enable pulse position input command
38: Disable write EEPROM function
39: Torque command direction
40: Force stop
41: Serial position clock
42: Serial position input
43: Analog input resolution selection