DA 62 AFM
Emergency
Procedures
3.11 FAILURES IN THE ELECTRICAL SYSTEM
3.11.1 COMPLETE FAILURE OF THE ELECTRICAL SYSTEM
1. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check if all OK (pressed in)
If there is still no electrical power available:
2. Map Light, if necessary . . . . . . . . . . . . . . . . . ON
3. POWER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . set based on lever positions and
engine noise
4. Prepare landing with flaps in the given position. Refer to 4B.5 - FAILURES IN FLAP
OPERATING SYSTEM.
5. Land on the nearest suitable airfield.
WARNING
Engine stoppage may occur, depending on the failure mode.
Backup batteries are installed for the ECUs to provide
electrical power solely to the ECU and their systems for at
least 30 minutes.
NOTE
The landing gear uplock is no longer ensured. The landing
gear may slowly extend.
The landing gear can be extended manually according to
3.9.2 - MANUAL EXTENSION OF THE LANDING GEAR.
CONTINUED
Doc. No. 11.01.05-E Rev. 0 11-Jan-2019 Page 3 - 57