EasyManua.ls Logo

Diamond DA 62 - L;R Gbox Temp

Diamond DA 62
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA 62 AFM
Emergency
Procedures
3.2.5 L/R GBOX TEMP
L/R GBOX TEMP
Left/Right engine gearbox temperature is in the upper
red range (too high/above 120 °C).
Gearbox temperatures above the limit value of 120 °C can lead to a total loss of power
due to engine failure.
- Reduce power on affected engine.
- Increase airspeed.
CAUTION
At high ambient temperature conditions, and/or at low
airspeeds with high power settings, it can be assumed that
there is no technical defect in the gearbox and that the above
mentioned procedure will decrease the temperature(s). This
might not be the case if the gearbox temperature does not
return to the green range. In this case, perform a
precautionary landing on the nearest suitable airfield. Prepare
for an engine failure in accordance with 3.7.6 - ENGINE
FAILURES IN FLIGHT.
END OF CHECKLIST
Doc. No. 11.01.05-E Rev. 0 11-Jan-2019 Page 3 - 11