EasyManua.ls Logo

Diamond DA 62 - L;R Aux Fuel Transfer Fail

Diamond DA 62
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA 62 AFM
Abnormal Operating
Procedures
4B.10 L/R AUX FUEL TRANSFER FAIL (IF AUX. TANKS ARE
INSTALLED)
If the fuel quantity in a main tank does not increase during fuel transfer:
1. Switch OFF both AUX PUMPS.
2. Check fuel pump LH/RH OFF.
CAUTION
An imbalance in the auxiliary tanks is approved when the
imbalance in the main tanks is less than 1 US gal (3.8 liters).
3. Check fuel imbalance in the main tanks; use CROSSFEED function (above 10000
ft turn LH/RH FUEL PUMP to ON before crossfeed operation) to keep the LH and
RH main tank imbalance within the permissible limit of 1 US gal (3.8 liters).
4. Switch the remaining AUX PUMP ON.
5. Use crossfeed function to keep the LH and RH main tank imbalance within the
permissible limit of 1 US gal (3.8 liters).
END OF CHECKLIST
Doc. No. 11.01.05-E Rev. 0 11-Jan-2019 Page 4B - 43