Abnormal Operating
Procedures
DA 62 AFM
4B.2.7 VOLTAGE
(a) Low Voltage Indication on the Ground with Engines Running
1. ALTERNATORS . . . . . . . . . . . . . . . . . . . . . . check ON
2. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check
If LOW VOLTAGE CAUTION (LOW VOLTS/4B.4.5) is still indicated on the G1000:
- Terminate flight preparation.
(b) Low Voltage During Flight
1. ALTERNATORS . . . . . . . . . . . . . . . . . . . . . . check ON
2. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check
3. Electrical equipment. . . . . . . . . . . . . . . . . . . . OFF if not needed
If LOW VOLTAGE CAUTION (LOW VOLTS/4B.4.5) is still indicated on the G1000:
- Follow procedure in 4B.4.6 - L/R ALTN FAIL.
END OF CHECKLIST
Page 4B - 10 Rev. 0 11-Jan-2019 Doc. No. 11.01.05-E