EasyManua.ls Logo

Diamond DA 62 - 3.6 L;R Altn Fail

Diamond DA 62
506 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Abnormal Operating
Procedures
DA 62 AFM
4B.3.6 L/R ALTN FAIL
L/R ALTN FAIL
Left/Right engine alternator has failed.
(a) One Alternator Failed
1. ALTERNATOR. . . . . . . . . . . . . . . . . . . . . . . . OFF/affected side
2. Bus voltage . . . . . . . . . . . . . . . . . . . . . . . . . . monitor
3. Electrical consumers . . . . . . . . . . . . . . . . . . . reduce as practicable
END OF CHECKLIST
(b) Both Alternators Failed
Proceed according to:
3.3.1 - L/R ALTN FAIL
END OF CHECKLIST
Page 4B - 20 Rev. 0 11-Jan-2019 Doc. No. 11.01.05-E

Table of Contents