Emergency
Procedures
DA 62 AFM
NOTE
The Standby Attitude Module will have electrical power for
at least 1.0 hours.
Make use of the Standby Attitude Module. Engine power can be set via visual reference
of the POWER lever position.
END OF CHECKLIST
3.11.2 HIGH CURRENT
If high current is indicated on the G1000:
1. Circuit breakers . . . . . . . . . . . . . . . . . . . . . . . check
2. Reduce electric load to minimum required for continued safe flight.
3. Land on the nearest suitable airfield.
END OF CHECKLIST
Page 3 - 58 Rev. 0 11-Jan-2019 Doc. No. 11.01.05-E