3.13.5 FUEL SUPPLY FAILURE
1. FUEL SELECTOR . . . . . . . . . . . . . . . . . . . . CROSSFEED/affected engine
(above 10000 ft turn LH/RH FUEL
PUMP to ON before crossfeed
operation)
WARNING
In case of a fuel supply failure, a fuel pump inspection is
required prior to the next flight.
2. Fuel quantity . . . . . . . . . . . . . . . . . . . . . . . . . monitor
3. Fuel pump of affected engine . . . . . . . . . . . . ON
If fuel supply failure remains:
4. FUEL SELECTOR . . . . . . . . . . . . . . . . . . . . . ON
5. Fuel pump of affected engine . . . . . . . . . . . . ON
6. Fuel quantity . . . . . . . . . . . . . . . . . . . . . . . . . monitor
END OF CHECKLIST